Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

6 1/2 in

d

6.500 in

D

8.858 in

L

1.496 in

L1

1.732 in

L2

2.283 in

Mt

31,210 ft-lbs

Fax

115,236 lbs.F

Ps

31434 psi

Ph

23065 psi
DN1 15.604 in

Locking Screws Quantity

22

Locking Screws Size

M14 x 40

Ma-Locking Screws

140 ft-lbs

dB-Locking Screws

M16

Hub Machining Tolerance

0.004 in

Shaft Machining Tolerance

-0.004 in

Weight

13.20 lb

UPC Code

044861086360

Downloads

Catalog Page
Installation & Removal Instructions
Installation Demonstration (Video)
Keyless Locking Technical Information
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Information.
^