Drop-in replacement for commonly used hex nut keyless bushings. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

1 15/16 in

d

1.938 in

D

2.875 in

D1

3.189 in

L

1.724 in

L1

2.000 in

L2

2.236 in

L3

2.472 in

Mt

10,603 in-lbs

Fax

10,943 lbs.F

Ps

5,993 psi

Ph

4038 psi
DN1 3.146 in

Locking Screws Quantity

8

Locking Screws Size

M6 x 20

Ma-Locking Screws

150 in-lbs

Hub Machining Tolerance

±.003 in

Shaft Machining Tolerance

±.003 in

Weight

1.98 lb

UPC Code

044861060117

Downloads

Catalog Page
Installation & Removal Instructions
Installation Demonstration (Video)
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.
^