Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

1 1/8 in

d

1.125 in

D

2.165 in

L

0.669 in

L1

0.886 in

L2

1.122 in

L3

1.358 in

Mt

352 ft-lbs

Fax

7,518 lbs.F

Ps

26,485 psi

Ph

13760 psi
DN1 2.970 in

Locking Screws Quantity

6

Locking Screws Size

M6 x 20

Ma-Locking Screws

10 ft-lbs

Hub Machining Tolerance

0.002 in

Shaft Machining Tolerance

-0.002 in

Weight

0.80 lb

UPC Code

044861074046

Downloads

Catalog Page
Installation & Removal Instructions
Installation Demonstration (Video)
Keyless Locking Technical Information
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Information.
^