Drop-in replacement for commonly used hex nut keyless bushings. Mounted component remains fixed axially during installation.

View Catalog Page
Installation & Removal Instructions
Unit of Measure
Items
C192 product Image

Series C192 Metric Locking Assembly

C192 product Image

Series C192 Metric Locking Assembly

C192 product Image

Series C192 Metric Locking Assembly

C192 product Image

Series C192 Metric Locking Assembly

C192 product Image

Series C192 Metric Locking Assembly
Calculator N/A Climax Hub OD Calculator
N/A Climax Hub OD Calculator
N/A Climax Hub OD Calculator
N/A Climax Hub OD Calculator
N/A Climax Hub OD Calculator
Dimensional Drawing N/A
Metric Locking Assembly
Shaft Size N/A 15 mm N/A 16 mm N/A 17 mm N/A 18 mm N/A 19 mm
d N/A 0.591 in N/A 0.630 in N/A 0.669 in N/A 0.709 in N/A 0.748 in
D N/A 1.496 in
D1 N/A 1.693 in
L N/A 0.551 in
L1 N/A 0.750 in
L2 N/A 0.984 in
L3 N/A 1.220 in
Mt N/A 1,620 in-lbs N/A 1,726 in-lbs N/A 1,832 in-lbs N/A 1,938 in-lbs N/A 2,045 in-lbs
Fax N/A 5,471 lbs.F
Ps N/A 26,283 psi N/A 24,641 psi N/A 23,191 psi N/A 21,903 psi N/A 20,750 psi
Ph N/A 10375 psi
DN1 N/A 1.892 in
Locking Screws Quantity N/A 4
Locking Screws Size N/A M6 x 20
Ma-Locking Screws N/A 150 in-lbs
Hub Machining Tolerance N/A ±.003 in
Shaft Machining Tolerance N/A ±.003 in
Weight N/A 0.44 lb
UPC Code N/A 044861060148 N/A 044861060155 N/A 044861060162 N/A 044861060179 N/A 044861060186
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.
^