Print Back
Drop-in replacement for commonly used hex nut keyless bushings. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

Climax Hub OD Calculator

Drawing

Dimensional Drawing


Locking Assembly

Specifications

Shaft Size

11/16 in

d

0.688 in

D

1.500 in

D1

1.693 in

L

0.551 in

L1

0.750 in

L2

0.984 in

L3

1.220 in

Mt

1,876 in-lbs

Fax

5,471 lbs.F

Ps

22,580 psi

Ph

10348 psi
DN1 1.896 in

Locking Screws Quantity

4

Locking Screws Size

M6 x 20

Ma-Locking Screws

150 in-lbs

Hub Machining Tolerance

±.003 in

Shaft Machining Tolerance

±.003 in

Weight

0.44 lb

UPC Code

044861059784

Downloads

Catalog Page
Installation & Removal Instructions
Installation Demonstration (Video)
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.